AMRCTL(8) System Manager's Manual AMRCTL(8)
NAME
amrctl - Control utility for AMI MegaRaid controllers
SYNOPSIS
amrctl stat [-bgv] [-a attempts] [-f device] [-l volno] [-p driveno]
[-s busno] [-s busno:driveno] [-t microseconds]
DESCRIPTION
The amrctl queries or controls AMI MegaRaid controllers supported by the
amr(4) driver.
Only the stat subcommand is currently implemented, and reports status of
the controller. The options for the stat subcommand are as follows:
-a attempts Number of retries for a command before giving up.
Default 5.
-b Report battery status.
-f device Device to use. Default to /dev/amr0.
-g Report global parameters for the controller.
-l volno Report status of a logical drive.
-p driveno Report status of a physical drive.
-s busno Report status of all physical drives on the specified
bus.
-s busno:driveno
Report status of the specified physical drive on the
specified bus.
-t microseconds
Delay between retries for a command.
-v Increase verbosity level by one.
SEE ALSO
amr(4)
HISTORY
The amrctl command first appeared in NetBSD 4.0.
AUTHORS
The amrctl command was written by Pierre David
<Pierre.David@crc.u-strasbg.fr> and
Jung-uk Kim <jkim@FreeBSD.org> for FreeBSD.
NetBSD 11.99 September 11, 2016 NetBSD 11.99